The HWg-PWR captures data from 12 external meters on the M-Bus and connects the data to IP. M-Bus data are available over Web (graphs), SNMP, Emails or Log files. With external M-Bus (EN 13757) meters it can be used for remote monitoring/metering of Electricity power, Heat, Water or Gas consumption. There are standard 3rd party M-Bus compatible meters on the market. HWg-PWR is reads data form external 12 M-Bus meters (EN 13757) and analyzes them. Up to 100 metered values can be shown on the WEB by graphs or monitored over SNMP.
The HWg-PWR M-Bus IP meter supports alarming through E-mail or SNMP traps whenever a defined value exceeds limit (current overload).
The M-Bus metering standard (EN 13757) is supported. There are certified meters with M-Bus interface from 3rd party vendors on the market (Electricity, Heat (calorimeters), Gas & Water meters). >> Supported M-Bus meters
With HWg-PWR you can simply monitor energy costs (Datacenters, Remote sites, Office buildings, Family houses)
Certified Electricity power meters with M-Bus interface are used for energy metering. You can use this data for billing your customers. No current or 1 phase limits. Simply install one 63 Amperes power meter per cabinet and monitor it remotely over SNMP.
Features
- Ethernet: RJ45 (10BASE-T)
- WEB: Embedded WEB server, graphs
- Data input: External M-Bus meters (EN 13757-2)
- M-Bus interface: Up to 12 meters (powered from HWg-PWR)
- M-Bus standards: EN 13757-2 (physical and link layer) & EN 13757-3 (application layer)
- Values limit: Up to 100 values from all meters
- Digital Inputs: 3 DI dry contact inputs
- Power: 230 V AC
- Housing: DIN rail montage
- M2M communication protocols: SNMP, XML, Syslog, Modbus/TCP
- Threshold Alerts: SNMP trap, Email
- Support for programmers: HWg SDK
- Supported software
- HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
- HWg-PDMS: Logging,export to MS Excel
- >> Third-party SNMP software
- Graphs: Logging of measured values with the option to plot graphs
- Counters: Independent energy counters for periodic readings (daily, weekly, monthly, annually, ...)
- Reports: Periodic e-mailing of acquired values over HTTP and by Email
- M-bus: Automatic detection of sensors and measured values (quantities)
- External M-bus meters
- You can use certified and calibrated meters
- Single-phase or 3-phase power meters can be used
- Support for single-tariff and multi-tariff meters
- M-Bus values (quantities) depend on the used meter only
- Typical values (quantities) examples
- Instantaneous power input
- Total consumption
- Line voltage
- Line current
- Flow speed
Usage examples
- Remote monitoring of power meters in small server rooms and BTS
- Monitoring of energy consumption in rented premises
- Acquiring energy consumption readings in remote or inaccessible areas
- Control over energy costs
- Checking for individual line overloads in three-phase wirings
- Checking for undervoltage in electric wirings
- Monitoring the flow of liquids
For the first steps, we recommend to use the HWg-PWR 1f 230V mobile box.