The RTR-505 allows for a variety of commercially available sensors to be connected to the included Input Module.
This new flexibility has widened the range of possible applications without having to change Base Units.
Download Data via Wireless Communication with a Base Unit
Recorded data can be downloaded from RTR-501, 502, 503, 505, and 574 Data Loggers (Remote Units) via wireless communication with a Base Unit. The wireless communication range between a Remote Unit and a Base Unit is about 150 meters [500 ft]. By registering an RTR-500 as a Repeater, it can be used to expand the wireless communication range.
Large Logging Capacity: Up to 16,000 Readings
RTR-501/502/505: Maximum of 16,000 readings
16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-501, RTR-502, or RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.
Low Energy Consumption Design
RTR-501/502/503/505
The RTR-501, RTR-502, RTR503 and RTR-505 Data Loggers use one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months.
Model names which include “L” are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.
All large battery pack models sold without battery (LS26500).
|
FCC model
|
RTR-505-TC/
505-TCL
|
RTR-505-Pt/
505-PtL
|
RTR-505-V/
505-VL
|
RTR-505-mA/
505-mAL
|
RTR-505-P/
505-PL
|
|
Measurement Items (*1)
|
Temperature
|
Voltage
|
4-20mA
|
Pulse
|
|
Recording Intervals
|
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. / 1, 2, 5, 10, 15, 20, 30, 60 min.
|
|
Logging Capacity
|
16,000 readings
|
|
Recording Modes
|
Endless: Upon reaching logging capacity, the oldest data is overwritten and recording continues.
One Time: Recording automatically stops when logging capacity is full.
* When using RTR-500NW or RTR-500AW as a Base Unit, only "Endless" can be selected.
|
|
LCD Displayed Items
|
Measurement, Recording Status, Recording Mode, Battery Life Warning, Unit of Measurement, Full (Logging Capacity FULL), Sensor Unconnected, Input Module Unconnected, Measurement Range Exceeded, Display Range Exceeded)
|
|
Power
|
Lithium Battery LS14250 (*2) x 1 / Lithium Battery CR2 x 1
For L type: Large Capacity Battery Adaptor Kit (RTR-500B1 /sold separately)
External Power Adaptor Kit (RTR-500A1 /sold separately)
|
|
Battery Life (*3)
|
About 10 months (for temperature measurement)
About 4 years (for temperature measurement with L type)
|
|
Radio Standard Specifications
|
FCC Part15 Section247 / IC RSS-210
(Frequency Range: 902 to 928MHz)
|
|
Wireless Transmission Range
|
About 150 meters (500ft) if direct and unobstructed
|
|
Communication Interfaces
|
Wireless Communication / Optical Communication
|
|
Communication Time
|
When downloading one Remote Unit at full logging capacity
Wireless Communication: about 2 min.
Optical Communication: about 160 sec.
|
|
Waterproof Capacity
|
Splash proof (rated for use in daily life) (*4)
|
|
Dimensions
|
H62mm x W 47mm x D19mm (excluding protrusions and sensor)
L type: D 46.5mm (with Large Capacity Battery Pack)
Antenna length: 24mm
|
|
Weight
|
About 55g (including battery / excluding Input Module)
L Type: about 109g (with Large Capacity Battery Pack)
|
|
Operating Environment
|
- 30 to 80°C (*5)
(The operating temperature range and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C.)
|
|
Other
|
A Base Unit is required separately.
|