CALL US : +386 41 612 309         English  
At TOTAL, all prices include VAT !

RFCurrent2000A Wireless Data Logger[RFC2000A]

RFCurrent2000A Wireless Data Logger[RFC2000A]

Your Price : 302,00 €
Quantity :

The RFCurrent2000A is a wireless data logger with LCD display, designed to measure and record DC current signals. The data logger can connect directly to low-level DC current sources which makes it ideal for (PV) Photovoltaic research to monitor current sourced from solar cells over time, battery usage studies, energy monitoring studies and other DC current monitoring applications. The RFCurrent2000A can also be interfaced with a wide range of current output sensors such as flow meters, pH transmitters and more. Through the MadgeTech software, the device can be programmed with engineering units, which convert the current readings into a different unit of measure, such as flow rate. The engineering unit is available for display on the LCD screen as well as within the software. The RFCurrent2000A is available in 20 mA, 160 mA or a 3 A measurement range.

The RFCurrent2000A can be used as a single, wireless data logging system, or can be expanded to a large scale system, which can include hundreds of data loggers measuring different parameters such as temperature, humidity and more (additional MadgeTech wireless data loggers and transceivers may be required). The RFCurrent2000A utilizes the latest MadgeTech 4 Software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.

CURRENT

Current Range

20 mA: -2 mA to 30 mA 
±160 mA: ±160 mA 
±3 A: ±3 A

Current Resolution

20 mA: 0.5 μA 
±160 mA: 5 μA 
±3 A: 100 μA

Current Calibrate Accuracy

20 mA, 160 mA: ±0.05 %FSR
3 A: ±0.15 %FSR

Current Input Impedance

20 mA: 10 Ω, ±1% 
±160 mA: 1 Ω, ±1%
±3 A: <0.05 Ω

WIRELESS

RF Carrier Frequency

2.45 GHz IEEE 802.15.4 ultra-low power MadgeNET Wireless Transceiver with fully by-directional communication.

Output Power

+0 dBm typical

Receiver Sensitivity

-95 dBm typical

Typical outdoors Line of sight

Up to 2000 ft

Typical Indoors line of sight

Up to 500 ft

GENERAL

Memory

32,256 readings per channel

Reading Rate

1 reading every second up to 1 reading every 24 hours

Baud Rate

250,000

Channels

1

LED Indicators

Green, Blue & Red

Battery Life

4 years typical at a 15 minute reading rate

Material

ABS plastic

Dimensions

20 mA & 3 A: 3.19 in x 3.5 in x 0.95 in (80.9 mm x 88.9 mm x 24.1 mm) - Data logger only 
160 mA: 3.17 in x 3.5 in x 0.95 in (80.5 mm x 88.9 mm x 24.1 mm) - Data logger only

IP Rating

IP22

Operating Environment

-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing

Required Interface Package

RFC1000 (wireless); USB to Mini USB Cable

Approvals

US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)